Home >> Electronics >> Gadgets >> Test Equipment >> MASTECH MS2108A Mini Digital Clamp Meter AC/DC Mini Digital Clamp Meter

MASTECH MS2108A Mini Digital Clamp Meter AC/DC Mini Digital Clamp Meter

SKU:A024000BTI

This meter is a portable professional measuring instrument with LCD and back light easily reading. The ‘single-hand operation’ design for the range switch makes measurement simple and easy. Overload protection and low battery indication are provided....
Retail Price:
USD$ 166.63
Wholesale Price:
 
Wholesale Price
Quantity 2-56-1415-39≥40
Price USD$ 33.77USD$ 33.02USD$ 32.28USD$ 31.28
 
Qty:
pieces
If you want to buy only 1 piece, please alter the quantity in ‘My Cart’.
Note: you could enjoy the wholesale price of this item as long as the item quantity of your order is more than 1.
  • For online wholesaler or distributor, you can buy directly online. If you want to buy more than offered quantities for better price, please click wholesale inquiry.

  • Top Selling
 
  • Overview


DESCRIPTION:

- The meter can perform measurements of AC/DC voltage and current, resistancefrequency, duty, capacitance, as well as continuity and diode test.
 Auto range is available.
- This meter is equipped with reading hold function.
- This meter is equipped with square value measuring function (at AC A and AC V range).
- This meter is equipped with auto zero function (at DCA range).
- This meter is equipped with maximum value measuring  function.
- This meter is equipped with minimum value measuring function.
- This meter can measure frequency by clamp.
- This meter has function of auto power off.

SPECIFICATIONS:


Calibration is required once a year, to be carried out at a temperature between 18°C and 28 °C (64°F to 82°F) and relative humidity below 75%.

GENERAL SPECIFICATIONS


Auto range.
Overrange protection is provided for all ranges.
Maximum voltage between terminals and earth ground: 1000V DC or 750V rms AC
Operating altitude: max. 2000 meters (7000 ft.)
Display: 4000 counts with analog bar LCD display
Maximum value display: 4000 digits
Polarity indication: automatic; '-' for negative polarity.
Overrange indication: '0L' or '-0L'
Converter Rate: 3 times/sec; Bar graph: 30 times/sec.
Unit indication: function and unit.
Auto power off time: 15 minute.
Operating power : 1.5V×3 AAA batteries
Battery low indication: ' ' on LCD
Temperature factor: < 0.1×Accuracy /℃
Operating temperature: 0℃ to 40℃32°F to 104°F
Storage temperature: -10℃ to 50℃10°F to 122°F
Dimension: 208×78×35mm
Weight: approximate 340gincluding batteries


ELECTRICAL SPECIFICATIONS:

Ambient temperature: 23±5℃    Relative humidity: < 75%

AC Current



Range

Resolution


Accuracy


40A


0.01A


±(2.0% of rdg + 6 digits)


400A


0.1A


 


- Max. input current: 400A AC
- Frequency range: 40 to 400Hz
- Response: average value

DC Current



Range

Resolution


Accuracy


40A


0.01A


±(2.0% of rdg + 6 digits)


400A


0.1A


 


- Max. input current:  400A DC

DC Voltage



Range

Resolution


Accuracy


400mV


0.1mV


± (1 .0% of rdg + 2digits)


4V


0.001V


 


40V


0.01V


± (0.7% of rdg + 2digits)


400V


0.1V


1000V


1V


±(0.8%rdg+2dgt)


- Input impedance: 10MW
- Max. input voltage: 1000V DC
NOTE:
At small voltage range, unsteady readings will appear before the test leads contact the circuit. This is normal because the meter is highly sensitive. When the test leads contact the circuit, the true reading will be shown.

AC Voltage



Range

Resolution


Accuracy


4V


0.001V


 


± (0.8% of rdg + 3digits)


40V


0.01V


400V


0.1V


750


1V


± (1% of rdg + 4digits)


- Input impedance: 10MW
- Max. input voltage: 750V rms AC
- Frequency range:  40 to 400Hz
- Response: average value

Frequency


1 By A range ( from current clamp):



Range

Resolution


Accuracy


10Hz


0.01Hz


 


±(1.5% of rdg + 5 digits)


1kHz


0.001KHz


>1kHz


0.001KHz


- Measurement range: 10 ~ 1kHz
- Input current range: ≥4A rms AC (higher input current at higher frequency)
- Max. Input current: 400A rms AC

2 By ACV range:



Range

Resolution


Accuracy


10Hz


0.01Hz


 


1kHz


0.001kHz


±(1.5% of rdg + 5 digits)


10kHz


0.01kHz


 


>10kHz


0.01kHz


Take it only as referance


- Measurement range: 10 ~ 10kHz
- Input voltage range: ≥ 0.6V rms AC (higher input voltage at higher frequency)
- Input impedance: 10MW
- Max. input voltage: 750V rms AC

3 By Hz/DUTY range



Range

Resolution


Accuracy


9.999Hz


0.001Hz


±(0.5% of rdg+3 digits)


99.99Hz


0.01Hz


999.9Hz


0.1Hz


9.999KHz


0.001 KHz


99.99KHz


0.01 KHz


999.9KHz


0.1 KHz


9.999MHz


0.001MHz


- Overload protection: 250V dc or 250V ac rms.
- Input Voltage range: 200mV-10V ac rms

Duty Cycle



Range

Resolution


Accuracy


0.1% - 99%


0.1%


± 3.0%


1 By A range ( from current clamp):

- Frequency response: 10 ~1kHz
- Input current range: ≥4A rms AC
- Max. input current: 400A

2 By ACV range:

- Frequency response: 10 ~ 10 kHz
- Input voltage range: ≥ 1 V rms AC
- Input impedance: 10MW
- Max. input voltage: 750V rms AC

3 By Hz/DUTY  range

- Frequency response: 1 ~ 10MHz
- Input voltage range: ≥ 500mV rms
- Overload protection: 250V rms AC

Resistance



Range

Resolution


Accuracy


400W


0.1W


 


± (0.8% of rdg + 3digits)


4kW


0.001kW


40kW


0.01kW


400kW


0.1kW


4MW


0.001MkW


40MW


0.1MW


± (1.2% of rdg + 3digits)


- Open circuit voltage: 0.4V
- Overload protection: 250V DC or rms AC

Diode



Range

Resolution


Function


  


0.001V


Displaying approximate forward voltage of diode


- Forward DC current ~ 1mA
- Reversed DC voltage ~ 3.3V
- Overload protection: 250V DC or rms AC


Continuity



Range

Resolution


Function


  


0. 1W


Built-in buzzer will sound, if resistance is lower than 40W.


- Open circuit voltage ~ 1.2V
- Overload protection: 250V DC or rms AC

Capacitance



Range

Resolution


Accuracy


40nF


0.01nF


 


400nF


0.1nF


 


4mF


0.001mF


±(4.0% of rdg + 5 digits)


40mF


0.01mF


 


400mF


0.1mF


 


4000mF


1mF


 


- Overload protection: 250V DC or rms AC

Item Show:

MASTECH MS2108A Mini Digital Clamp Meter AC/DC Mini Digital Clamp Meter

 


ACCESSORIES:

Test Leads: Electric Ratings 1000V 10A 1 Pair(Set)
Operating Manual 1 Copy
1.5V AAA Battery 3 piece